POINT
Estimated available time
※Some products may not be available.- POINT01
-
Low noise
- The Noise Power Level is as much as in the Shinkansen, so the generator can be run in the city.
- POINT02
-
High durability and reliability
- The generator can be run in an earthquake and emergency because of stable design.
※The generator equipped with MGC CARRY CART can easily be moved.
- The generator can be run in an earthquake and emergency because of stable design.
- POINT03
-
Wide selection of products
- MGC901GB can easily be run in an emergency or for leisure.
- MGC901GP can be connected to the custemer’s LP Gas cylinder and run for a long time.
SPEC
ALTERNATOR | TYPE | Revolving Field, Multi-pole, Single Phase, Inverter Generator | |
Exciting Type | Self-exciting | ||
Voltage Regulator | Inverter | ||
AC Frequency[Hz] | 50/60 Hz (Swittchable) | ||
Rated Output | AC[ kVA] | 0.9 | |
DC[ W] | 100 | ||
Rated Voltage | AC[ V ] | 100 | |
DC[V] | 12 | ||
Electric current | AC[A] | 9 | |
DC[A] | 8.3 | ||
Output terminal | AC | 2-Outlet with a ground wire | |
DC | 1-Land terminal | ||
Power Factor | 1 | ||
AC/DC current protection | ー | ||
ENGINE | Model | GM082 | |
Type | Air-cooled, 4-stroke, OHV, Gas Engine | ||
Displacementcm3 | 79.6 | ||
Fuel | Cassette (butane) Gas※1 | ||
Temperature limit℃ | 10〜40※2 | ||
Fuel Tank CapacityL | 500g (Two cassette gas are required.) | ||
Cont. Operating Capacity(1/4~Rated Output) h | About 1.6~1.0 | ||
Lubrication Oil | Eigine Oil SE Class or Higher, SAE#30, at Cold Latitude SAE#20 | ||
Lubrication Oil CapacityL | 0.4 | ||
Ignition Plug | BPR6HS | ||
Starting System | Recoil Starter | ||
Governor System | ー | ||
OTHER | Noise Power LeveldB/LWA | 91 (3/4 Output)※3 | |
Dimensions(L×W×H)[ mm] | 400×330×390 | ||
Dry weight[kg] | 22 | ||
Oil sensor | equipped |
※1 Could you inform the Cassette specification when making inquires from overseas, please?
※2 It may not be possible to run the Generator below 10℃ due to the specification of the cassette.
※3 Noise Power Level in a test condition according to ISO3744.
※2 It may not be possible to run the Generator below 10℃ due to the specification of the cassette.
※3 Noise Power Level in a test condition according to ISO3744.
OPTION
MGC901GP LP (propane) Gas
Rated Output |
Alternating current |
900VA |
---|---|---|
Continuous Operation time |
Rated Output | 10.0hr |
1/4 Output | 16.0hr |
(Using a 5kg cylinder)
MGC1003 Gasoline
Rated Output |
Alternating current |
1000VA |
---|---|---|
Continuous Operation time |
Rated Output | 5.0hr |
1/4 Output | 8.0hr |
MGC2200G LP (propane) Gas
Rated Output |
Alternating current |
2200VA |
---|---|---|
Continuous Operation time |
Rated Output | 10.0hr |
1/4 Output | 20.0hr |
(Using a 10kg cylinder)